Atomlab™ 960 Thyroid Uptake System
A complete, mobile, self-contained Medical Spectrometer System
The Atomlab 960 Thyroid Uptake System is an advanced multipurpose spectrum analysis instrument designed for diverse nuclear medicine applications. Uptake studies, wipe tests, and other user-defined tasks are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.
The system’s multichannel analyzer has 1024 channels, with individual MCAs for the probe and optional well counter. Engineered for mobility, durability and operational efficiency, the Atomlab 960 handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Intuitive menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout all defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.
The self-contained Atomlab 960 system is configured on a compact mobile platform with locking casters and a base that measures only 26" w by 34" l (66 x 86.4 cm). An upper shelf supports the flat panel PC with touch-screen display and keyboard. The stand provides convenient storage positions for Neck Phantom, Calibration/Constancy Fixture, and optional well counter. A 2" x 2" NaI(Tl) detector with collimator shield articulates on a multi-axis and height adjustable counterbalanced arm. The 24.5" (62.2 cm) of vertical travel allows the probe to be positioned from 30.5 to 55" (77.5 to 139.7 cm) in the horizontal position from the floor to accommodate seated or supine patients. The probe swings more than 180° on the horizontal plane, and extends outward, up to approximately 31" (78.7cm) horizontally from the support column. This design makes positioning for uptake studies simple and comfortable for both patient and technologist. The combination of positioning LED and distance measurement rod assures accurate, repeatable patient positioning and uptake measurements.
Comprehensive Clinical Software:
Extremely intuitive menus follow conventionally established nuclear medicine procedures. All programs provide clear, concise reports for referring physicians, insurance providers, patient records and a database for physician and technologist identification. PDF reports allow for easy electronic distribution.
Thyroid Uptake Program
The Atomlab 960 provides intuitive menus with provision to modify any procedure to suit specific requirements. Atomlab software guides the user through each step of any defined procedure. Automatic decay correction calculates elapsed time between dose count and actual patient thyroid count, and then automatically computes uptake percentage.
Wipe Test Program
Designed for use with the optional well counter, the Wipe Test Program makes it easy to comply with regulations for counting and reporting results of wipes taken for contamination surveys.
The user may define an unlimited number of “Area” names and wipe “Locations” entered within these areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotope and geometric efficiencies or simply utilize the wide range of factory default options.
The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may also be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.
Administration / Quality Assurance Program
There are a multitude of administration functions, each designed to minimize the time normally spent maintaining accurate use of the system. There is an automated high voltage setting for each detector, and an automatic calibration program using a Cs-137 source. The system will advise the user when a daily calibration has not been performed. The Chi-Square test program automatically performs the Chi-Square calculations and generates a printed report. Site information is entered in the administration program containing the facility name, address, and a list of the technologists and physicians in the department. Customized administrative and clinical reports can be printed or saved in PDF format.
Manual MCA Program
For performing sample counts and analysis beyond the scope of the standardized programs.
In addition to providing “standardized” programs for routine test and survey procedures, the 960 has a “manual” program to accommodate other counting and spectrum analysis tasks. The user can select from three counting methods: Preset Time, Preset ROI Counts, and Continuous Counting. After any count, the Spectrum Analysis option can be used to produce a Spectrum Analysis Report. The monitor shows when a test is in progress, and graphically displays the spectrum, time, counts and cpm.
Bioassay Program
For individual patients or employee groups
The Bioassay program of the Atomlab 960 allows for the quick and efficient measurement of the staff thyroid burden for I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. Report choices include single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports can easily be printed or saved as PDF files.
NEW DICOM Program
Optional - compliant to DICOM requirements.
The optional DICOM Program integrates the Atomlab 960 Thyroid Uptake System with your hospital management system, streamlining workflows and improving communication. The program allows you to retrieve patient information from the worklist and upload patient results, without exiting the clinical software, increasing staff productivity and efficiency. DICOM allows the uptake reports to be transferred, stored and queried/retrieved throughout a facility. Physicians can view both thyroid scans and uptake reports simultaneously.
![]() |
How to: Position Uptake Arm - Biodex Atomlab™ 960 Thyroid Uptake System Learn about the Atomlab™ 960 Thyroid Uptake arm components, how to properly move the probe, obtain uptake information and use the neck phantom to obtain a count standard. Components of the Uptake Arm and Positioning Tips: 00:05 For more information about Thyroid Uptake System accessories including the Neck Phantom, visit www.biodex.com/uptakeaccessories. |
|
187-600 |
Thyroid Uptake System, Atomlab 960 |
$15,750.00 |
Export models available.
187-146 | Interface, Atomlab 960, DICOM | $4,995.00 |
187-602 |
Well Counter, 1" Lead (2.5 cm) |
3,000.00 |
187-603 | Lead Shield, Well Counter, 1" Lead (2.5 cm) | 900.00 |
063-139 | Rod Source, Cs-137, Calibrated, 0.1 µCi | $380.00 |
101-103 | Check Source, Cs-137, 10 µCi* Uncalibrated, 1" dia x .25" thick (2.5 x .64 cm) |
190.00 |
043-365 | Thyroid Uptake Neck Phantom (Complete with bottle carrier, capsule holder and 12 polyethylene bottles) |
595.00 |
* Recommended Check Source for calibration of probe and well.
Request More Information
Conditions of Purchase
20 Ramsey Road
Shirley, New York
11967-4704
Problems viewing the site? Contact the webmaster.
Tel: (800) 224-6339
Int Tel: +1-631-924-9000
Fax: (631) 924-8355
Email: info@biodex.com
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
Read More